Nobel Biocare
Showing all 7 results
-
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area Models
NobelActive
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area ModelsNobelActive
NobelActive – an implant like no other
The unique implant design for high primary stability and esthetic excellence
Excellent primary stability
NobelActive is truly an implant like no other. No matter if you're dealing with soft bone, extraction sockets, or the esthetic region, you can benefit from its high primary stability. This makes NobelActive a suitable choice for demanding indications and protocols, such as immediate implant placement and Immediate Function.
Experience high primary stability even in demanding situations
NobelActive's expanding tapered implant body condenses bone gradually while the apex with drilling blades enables a smaller osteotomy.10 These features help to achieve high primary stability in demanding situations, such as soft bone or extraction sockets. NobelActive enables immediate implant placement and Immediate Function where it might otherwise be challenging
Aim for excellent esthetics
In the end, it's all about the final result. NobelActive's back-tapered coronal design and built-in platform shifting are designed to optimize bone and soft tissue volume for natural-looking esthetics.
Adjust your implant position during placement
Reverse-cutting flutes with drilling blades on the apex enable experienced clinicians to adjust the implant position during placement for an optimized restorative orientation, particularly in extraction sites.
Experience a strong conical connection
The internal conical connection with hexagonal interlocking offers high mechanical strength.14 This helps to ensure the necessary stability of the restoration for a predictable result.
Place implants in areas with limited space
NobelActive 3.0 is specifically designed for narrow space situations, such as lower incisors, where conventional implants previously could not be placed.
Achieve a natural molar emergence profile
You can now also benefit from NobelActive's unique design in the posterior region. The new Wide Platform (WP) implant is specifically designed for posterior cases that require a wider base. It helps create a natural-looking emergence profile for the molar crown, and its shorter implant body (7mm) helps to avoid critical anatomical structures.
Enhanced osseointegration
NobelActive features our unique oxidized TiUnite surface. It maintains high stability during healing through fast bone formation and promotes long-term success.
Lifetime warranty
NobelActive is covered by a lifetime product warranty.
SKU: n/a -
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area Models
NobelActive 3.0
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area ModelsNobelActive 3.0
Narrow space solutions – NobelActive 3.0
Safe implant placement in areas with limited space
The implant for narrow spaces
NobelActive 3.0 is ideal for areas with limited space, such as missing lateral incisors. It provides the high implant strength that is usually difficult to achieve with small diameter implants. Tests indicate superior fatigue and torque strength compared to other 3.0 mm implants on the market.
Place implants safely in areas with limited space
We designed the NobelActive 3.0 specifically for narrow space situations where you previously wouldn't have been able to place a conventional implant. With NobelActive 3.0, you're able to treat single-unit maxillary lateral incisors as well as mandibular lateral and central incisors.
Get peace of mind – safe clinical solution
Narrow diameter implants (Ø < 3.5 mm) allow you to safely and predictably treat situations where traditional diameter implants would increase the clinical risk. That could, for example, be indications with minimal hard tissue and limited space. The clinical performance of narrow implants has been validated in several studies with follow-up of up to seven years. Results show an overall survival rate of 97.3% after five years, proving that narrow implants present a safe clinical solution.
High fatigue strength
The fatigue strength of NobelActive 3.0 with an Esthetic Abutment has been tested according to ISO Standard 14801:2007, with an achieved strength of 160N. The Brånemark System NP implant, which has been in clinical use with very low complication rates since 1996, has a corresponding strength of 178N. As NobelActive 3.0 has restricted indications compared to the Brånemark System, it will be subjected to lower loads.
In comparison, fractures occurred at much lower load levels with narrow diameter implants from other manufactures.
High torque strength
NobelActive 3.0 is designed to withstand more than twice the recommended maximum insertion torque of 45 Ncm. Tests with a torque above 100 Ncm did not damage either the implant, interface or driver.
Enhanced osseointegration
NobelActive 3.0 features Nobel Biocare’s unique oxidized TiUnite surface with grooves (Groovy). This increases implant stability through faster bone formation and ensures long-term success.
Benefit from the unique design of NobelActive
With NobelActive 3.0 you enjoy all the same benefits as the regular NobelActive implant.
Lifetime warranty
NobelActive 3.0 is covered by a lifetime product warranty.
SKU: n/a -
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area Models
NobelDirect 3.0
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area ModelsNobelDirect 3.0
The NobelDirect 3.0 implant encompasses the osseous component and restorative component in one piece. This design is based on the One-Stage Placement concept and offers a number of possible advantages :
- New indications : NobelDirect 3.0 is the first FDA-cleared implant on the market with a diameter of 3.0 mm. For the first time the mandibular central and lateral incisors or maxillary lateral incisors can be restored with an excellent esthetic outcome.
- Ease-of-use : The NobelDirect 3.0 implant is a threaded one-piece implant with an integrated abutment designed for one-stage surgical procedures and cemented restorations.
- Tissue friendliness : The surgery is performed only once, allowing the soft tissue to adapt to the implant / abutment interface without further manipulation.
- Esthetics : The abutment can be prepared to an optimized adaptation to the gingival margin
- The TiUnite surface on NobelDirect 3.0 : Due to a more rapid formation and greater amount of bone to implant contact during healing, Nobel Biocare's Ti-Unite® surfaced implants result in faster and stronger osseointegration and better maintenance of the initial implant stability than machined titanium implants.
Treatment Planning
Indication for use
The diameter of two-piece implants is limited due to the lesser strength of the hollow implant body and the screwjoint. The one-piece design overcomes this limitation and allows us to offer a special small diameter implant – NobelDirect 3.0. This implant is intended for use in the tight space challenges in the region of the mandibular central and lateral incisors and maxillary lateral incisors with a delayed loading protocol.
When the implant is placed it should be restored with a Healing Cap or temporary crown without occlusal loading during the healing time.
Inclusion / Exclusion criteria
The following criteria are recommended for the use of NobelDirect 3.0
- Good gingival / periodontal / periapical status of adjacent teeth
- Favorable and stable occlusal relationship
- No apical disorder / inflammation at the area of the implant site or adjacent teeth
- Good bone volume and density
- No cantilevered restorations
- Angulation requirements of the restoration not exceeding 100
- High initial implant stability
- Controlled loads
The treatment plan should identify and reduce potential load factors such as lateral occlusal contacts, unstable dental occlusion and severe bruxism or other pronounced parafunctions.
Pretreatment Considerations
- The crestal gingiva must be of adequate width if the tissue punch is to be used. In addition, the facial gingiva must also be of an adequate thickness and width to enable sufficient vestibular depth.
- In the presence of an inadequate quantity of gingiva, shallow vestibular depth, and/or frenula pulling, a free gingival graft must be placed at least 3 months before placing the NobelDirect 3.0 implants.
- In the presence of a severely resorbed alveolar ridge, bone augmentation may be required.
Radiographic Examinations
Implant templates that are actual size or magnified 130% or 170% are supplied for NobelDirect 3.0 and used in conjunction with radiographic imaging as a guide to selecting the proper implant to be used. These overlays are to be used as guides only. When more accurate measurements are required, radiographic techniques such as tomograms and computerized tomographic (CT) scans should be utilized.
Additional diagnostic radiographic imaging may be indicated to determine the quality and quantity of alveolar bone or to identify anatomical landmarks.
Implant placement with Flap Reflection
A flap approach is recommended if adequate bone has not been confirmed, if direct vision of anatomic landmarks is necessary or if the facial gingival surface needs connective tissue augmentation.
Implant placement immediately after extraction
The healing capacity of an extraction site is excellent and, as long as the initial stability is reached, implant therapy is well suited to extraction sites. In addition to the above criteria, careful removal of any soft tissue and / or infected tissue is required. If periodontitis is the cause of the extraction, healing before implant treatment is often the procedure of choice.
The following steps are recommended for placement at time of extraction :
- Carry out gentle extraction, where possible keeping the labial bone plate intact
- Carefully remove remnants of any soft tissue from the socket
- Select the length of the implant so its apical end extends beyond the extraction socket
- Using the drills and drill guide, align the preparation as it should ideally be, independent of the direction of the tooth root/extraction socket
- Make optimal use of the interproximal walls for stability
- For immediate placement after an extraction, ensure that the gap between the implant and the bone wall is as small as possible
- Ensure that soft tissue closure around the implant is complete, as this is essential. Vestibular incisons may be required
Flapless Implant Placement
Flapless surgery is indicated in situations where adequate bone and attached gingiva are present, as well as sufficient vestibular depth.
Note: Available bone and significant anatomical landmarks such as blood vessels, nerves and concavities have to be confirmed with conventional diagnostic tools such as radiographic imaging, probing and palpation.
SKU: n/a -
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area Models
NobelRaeplace Select
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area ModelsNobelRaeplace Select
NobelReplace Select- one implant system for all your needs
The well-established and easy-to-use implant system with four options for high treatment flexibility
The original tapered implant
NobelReplace and the original tapered implant Replace Select mimic the shape of a natural tooth root. They are designed for high initial stability in all loading protocols, including Immediate Function.
Experience the highly tactile feel
The easy-to-use connection has three interlocking channels for secure and accurate abutment placement.
Simplify treatment with a straightforward surgical protocol
The surgery kit has a step-by-step drilling protocol and all components are consistently color-coded. This simplifies site preparation and ensures a predictable outcome.
Achieve high initial stability even in compromised bone
The original tapered implant mimicking the shape of a natural tooth root is designed for high initial stability. NobelReplace and Replace Select Tapered are ideal for Immediate Function in both extraction sockets and healed sites.
Choose between four options for high treatment flexibility
Cover your clinical needs with only one system. Whatever your patient’s requirements and personal preference, the four implant options ensure total treatment flexibility.
Enhanced osseointegration
NobelReplace and Replace Select Tapered feature Nobel Biocare’s unique oxidized TiUnite surface with grooves (Groovy), which maintains high stability during healing through faster bone formation and ensures long-term success
Lifetime warranty
NobelReplace and Replace Select Tapered are covered by a lifetime product warranty.
SKU: n/a -
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area Models
NobelReplace
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area ModelsNobelReplace
NobelReplace – one implant system for all your needs
The well-established and easy-to-use implant system with four options for high treatment flexibility
The original tapered implant
NobelReplace and the original tapered implant Replace Select mimic the shape of a natural tooth root. They are designed for high initial stability in all loading protocols, including Immediate Function.
Experience the highly tactile feel
The easy-to-use connection has three interlocking channels for secure and accurate abutment placement.
Simplify treatment with a straightforward surgical protocol
The surgery kit has a step-by-step drilling protocol and all components are consistently color-coded. This simplifies site preparation and ensures a predictable outcome.
Achieve high initial stability even in compromised bone
The original tapered implant mimicking the shape of a natural tooth root is designed for high initial stability. NobelReplace and Replace Select Tapered are ideal for Immediate Function in both extraction sockets and healed sites.
Choose between four options for high treatment flexibility
Cover your clinical needs with only one system. Whatever your patient’s requirements and personal preference, the four implant options ensure total treatment flexibility.
Enhanced osseointegration
NobelReplace and Replace Select Tapered feature Nobel Biocare’s unique oxidized TiUnite surface with grooves (Groovy), which maintains high stability during healing through faster bone formation and ensures long-term success
Lifetime warranty
NobelReplace and Replace Select Tapered are covered by a lifetime product warranty.
SKU: n/a -
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area Models
NobelReplace Conical Connection
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area ModelsNobelReplace Conical Connection
NobelReplace Conical Connection – proven stability, high esthetics
The implant system that combines the proven tapered implant body with a tight sealed connection
An esthetic solution for all indications
NobelReplace Conical Connection merges the original tapered implant body with a tight sealed conical connection, offering you and your patients an esthetic solution for all indications. The implant body mimics the shape of a natural tooth root, ensuring high initial stability for all loading protocols, including Immediate Function.
Experience the strong sealed connection
The implant-abutment interface is crucial for a long-lasting functional and esthetic result. The internal conical connection offers a tight seal and high mechanical strength.8 This gives the restoration the stability required for a predictable result.
Deliver a natural-looking esthetic result
Soft tissue volume is key to an esthetic result. The built-in platform-shifting feature provides a small ridge on which soft tissue can develop. This increases soft tissue volume and ensures a natural-looking result.
Achieve high initial stability, even in compromised bone
The original tapered implant, NobelReplace, mimics the shape of a natural tooth root. Designed for high initial stability, it's ideal for Immediate Function in both extraction sockets and healed sites
Simplify the treatment with a straightforward surgical protocol
The surgery kit has a step-by-step drilling protocol and consistently color-coded components. This simplifies site preparation and ensures a predictable outcome.
Choose between two collar options
Depending on your clinical need and treatment preference, you have the choice between NobelReplace Conical Connection with TiUnite on the collar or NobelReplace Conical Connection PMC with 0.75 mm machined collar.
Enhanced osseointegration
NobelReplace Conical Connection features Nobel Biocare’s unique oxidized TiUnite surface with grooves (Groovy). TiUnite maintains high stability during healing through faster bone formation, helping to ensure long-term success
Lifetime warranty
NobelReplace Conical Connection is covered by a lifetime product warranty.
SKU: n/a -
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area Models
OsseoSet 200
Conservative Dentistry, Dental Simulator Education, Dental Training Products, Endodontics Area ModelsOsseoSet 200
OsseoSet™ 200 SI-915, 115V,Complete drill solution – OsseoSet 200 with a broad range of accessories for implant and prosthetic treatments,Safe treatments – High performance drilling and precise torque control,Superior handling – Separate programs and ergonomic foot control.
Complete Drill Solution optimized for implant treatments and prosthetics. Torque release function enables safe and easy treatments. Designed for 20:1 and contra angled and 1:1 straight handpieces Motor is sterilizable and maintenance free. Unused but without original manufacturer packaging. Enables internal and/or external irrigation.
SKU: n/a