, , ,

STATIM 5000 G4 Endo (Ext.Cassette)





SciCan is proud to unveil the newest STATIM family member, the G4 series. The STATIM G4 series is the same renowned and trusted autoclave it has been for over 20 years but now boasts a new contemporary look, functionality and connectivity that is the first of its kind. The G4 technology will change the way you interact by providing a direct channel of communication through the Internet to increase productivity and limit downtime.

STATIM 5000 G4 Endo (Ext. Cassette) benefits :

  • Endo container for Endo Cassette STATIM 5000
  • LCD touch screen control
  • Networking capability
  • Integrated printer option

STATIM'S SPEED

Reduces Instrument Investment

STATIM sterilizes handpieces and instruments for immediate use in as little as 8 minutes, reducing the number required as instruments can be processed ‘just in time’ or between patients.

Increases Efficiency

Fast point-of-use sterilization makes turnaround a priority, increasing efficiency and virtually eliminates instrument bottlenecks.

Gentle on Instruments

Our state-of-the-art steam technology is gentle on both solid and hollow instruments.

THE STATIM DIFFERENCE.

Immediate Steam Generation

Unlike conventional autoclaves that need to heat an entire reservoir of water, STATIM uses only a small, specific amount of water required for each cycle. Water is introduced into a heating device referred to as a ‘steam generator’, rapidly heated and converted to steam in mere seconds.

Air Removal

Using PPPD technology and our patented steam injection process – air is automatically forced out of the sterilization chamber.

Cassette System

The thin stainless steel walls of STATIM’s fully-removable cassette, (or sterilization chamber) allow for rapid heating and cooling of the chamber. As a result, STATIM meets the conditions for sterilization and drying in a fraction of the time required by a conventional autoclave.

Drying Technology

The STATIM 2000 and 5000 have each been designed to provide you with a complete solution: rapid sterilization balanced by rapid drying. Introducing STATIM Dri-Tec drying technology.



Total Cycle time w/o drying Solid Unwrapped Hollow Unwrapped Hollow Unwrapped Hollow Unwrapped Hollow Unwrapped Rubber/ Plastic Rubber/ Plastic
Sterilisation time / temp 3,5 min./ 1340C 3,5 min./ 1340C 18 min./ 1340C 3,5 min./ 1340C 18 min./ 1340C 15 min./ 1210C 30 min./ 1210C
STATIM 2000 G4 6:45 8:05 22:35 10:40 25:10 18:40 33:40
STATIM 5000 G4 8:45 10:50 25:20 15:30 30:00 20:20 35:20


Rp 0

Brand

SciCan

SHOPPING CART

close